TMP-12Calibration Laboratory
Temperature Devices Calibration
From thermocouples to dry-block calibrators, spanning -80 °C to +1200 °C — in our accredited laboratory, we provide precise calibration across every field of temperature metrology with reference standards.
Accredited CalibrationACCREDITATIONTÜRKAK
SCOPE91 device types
STANDARDISO/IEC 17025
Calibration Scope
Devices we calibrate
| No. | Device | Measuring range | Certificate type |
|---|---|---|---|
| 01 | Analogue ThermometerITS-90 | Measuring range:−40 °C ≤ T ≤ 1200 °C | TÜRKAK |
| 02 | AutoclaveITS-90 | Measuring range:100 °C ≤ T ≤ 150 °C | TÜRKAK |
| 03 | Climatic ChamberEURAMET cg-20 · DAkkS-DKD-R 5-7 | Measuring range:−80 °C ≤ T ≤ 250 °CMeasuring range:10 %rh ≤ RH ≤ 90 %rh | TÜRKAK |
| 04 | Clinical Thermometer | TÜRKAK | |
| 05 | Cold Room / Cold StorageITS-90 | Measuring range:−80 °C ≤ T ≤ 250 °C | TÜRKAK |
| 06 | Concora Medium Fluter | TÜRKAK | |
| 07 | Cooking Oil Tester (Temperature) | TÜRKAK | |
| 08 | Curing Tank | TÜRKAK | |
| 09 | Deep Freezer | Measuring range:−80 °C ≤ T ≤ 250 °C | TÜRKAK |
| 10 | Dew Point Meter | Measuring range:20 %rh ≤ RH ≤ 90 %rh | TÜRKAK |
| 11 | Dry Block CalibratorITS-90 | Measuring range:−80 °C ≤ T ≤ 1200 °C | TÜRKAK |
| 12 | Drying FurnaceEURAMET cg-20 · DAkkS-DKD-R 5-7 | TÜRKAK | |
| 13 | Drying Machine | TÜRKAKTraceable | |
| 14 | Drying OvenEURAMET cg-20 · DAkkS-DKD-R 5-7 | Measuring range:−80 °C ≤ T ≤ 250 °C | TÜRKAK |
| 15 | Ductility Tester | TÜRKAK | |
| 16 | Fermentation Room | TÜRKAK | |
| 17 | Flash Point Tester | TÜRKAK | |
| 18 | Glow Wire Tester | TÜRKAK | |
| 19 | Humidity Transmitter | Measuring range:20 %rh ≤ RH ≤ 90 %rh | TÜRKAK |
| 20 | Hygrometer (Ambient)ITS-90 | Measuring range:20 %rh ≤ RH ≤ 90 %rh | TÜRKAK |
| 21 | IncubatorEURAMET cg-20 · DAkkS-DKD-R 5-7 | Measuring range:−80 °C ≤ T ≤ 250 °C | TÜRKAK |
| 22 | Liquid BathITS-90 | Measuring range:−80 °C ≤ T ≤ 250 °C | TÜRKAK |
| 23 | Liquid-in-Glass ThermometerITS-90 | Measuring range:−40 °C ≤ T ≤ 250 °C | TÜRKAK |
| 24 | Melting Point Apparatus | TÜRKAK | |
| 25 | MFI / Melt Flow Indexer | TÜRKAK | |
| 26 | Muffle FurnaceEURAMET cg-20 · DAkkS-DKD-R 5-7 | Measuring range:400 °C ≤ T ≤ 1200 °C | TÜRKAK |
| 27 | Multichannel Temperature Calibrator | TÜRKAK | |
| 28 | Multifunction Temperature Calibrator | Measuring range:Thermocouple: −270 °C ≤ T ≤ 1370 °CMeasuring range:RTD: −200 °C ≤ T ≤ 650 °C | TÜRKAK |
| 29 | Oil BathITS-90 | Measuring range:−80 °C ≤ T ≤ 250 °C | TÜRKAK |
| 30 | OvenEURAMET cg-20 · DAkkS-DKD-R 5-7 | TÜRKAK | |
| 31 | Ozone Ageing Chamber | TÜRKAK | |
| 32 | Pour Point Tester | TÜRKAK | |
| 33 | Pyrometer | Measuring range:−40 °C ≤ T ≤ 1200 °C | TÜRKAK |
| 34 | Radiation / Infrared ThermometerITS-90 | Measuring range:−40 °C ≤ T ≤ 1200 °C | TÜRKAK |
| 35 | Reference Resistance ThermometerITS-90 | Measuring range:−40 °C ≤ T ≤ 400 °C | TÜRKAK |
| 36 | Reference Thermo-hygrometerITS-90 | Measuring range:−30 °C ≤ T ≤ 150 °CMeasuring range:20 %rh ≤ RH ≤ 90 %rh | TÜRKAK |
| 37 | Reference Thermocouple ThermometerITS-90 | Measuring range:−40 °C ≤ T ≤ 1200 °C | TÜRKAK |
| 38 | Reference Thermometer | Measuring range:−40 °C ≤ T ≤ 1200 °C | TÜRKAK |
| 39 | Reference Thermometer (Indicator) | Measuring range:−40 °C ≤ T ≤ 1200 °C | TÜRKAK |
| 40 | Refrigerated VehicleITS-90 | TÜRKAK | |
| 41 | RefrigeratorITS-90 | Measuring range:−80 °C ≤ T ≤ 250 °C | TÜRKAK |
| 42 | Resistance ThermometerITS-90 | Measuring range:−40 °C ≤ T ≤ 400 °C | TÜRKAK |
| 43 | RheometerITS-90 | TÜRKAK | |
| 44 | Room / Ambient Thermometer | Measuring range:−30 °C ≤ T ≤ 150 °C | TÜRKAK |
| 45 | Salt BathEURAMET cg-20 · DAkkS-DKD-R 5-7 | TÜRKAK | |
| 46 | Salt Spray Corrosion ChamberITS-90 | TÜRKAK | |
| 47 | Softening Point Apparatus | TÜRKAK | |
| 48 | SteriliserEURAMET cg-20 · DAkkS-DKD-R 5-7 | Measuring range:−80 °C ≤ T ≤ 250 °C | TÜRKAK |
TÜRKAKwithin our TÜRKAK accreditation scope, certificate with accreditation markTraceablecalibration certificate traceable to national / international referencesrows with an arrow open all ranges and a scope check
Showing 48 / 91 devicesCan’t find your device on the list? Ask us →
From our laboratory
Temperature Devices
Some of the 91 device types in our calibration scope.



Türkçe