TMP-12Calibration Laboratory

Temperature Devices Calibration

From thermocouples to dry-block calibrators, spanning -80 °C to +1200 °C — in our accredited laboratory, we provide precise calibration across every field of temperature metrology with reference standards.

Temperature Device CalibrationAccredited Calibration
ACCREDITATIONTÜRKAK
SCOPE91 device types
STANDARDISO/IEC 17025
Calibration Scope

Devices we calibrate

Scope
No.DeviceMeasuring rangeCertificate type
01Analogue ThermometerITS-90Measuring range:−40 °C ≤ T ≤ 1200 °CTÜRKAK
02AutoclaveITS-90Measuring range:100 °C ≤ T ≤ 150 °CTÜRKAK
03Climatic ChamberEURAMET cg-20 · DAkkS-DKD-R 5-7Measuring range:−80 °C ≤ T ≤ 250 °CMeasuring range:10 %rh ≤ RH ≤ 90 %rhTÜRKAK
04Clinical ThermometerTÜRKAK
05Cold Room / Cold StorageITS-90Measuring range:−80 °C ≤ T ≤ 250 °CTÜRKAK
06Concora Medium FluterTÜRKAK
07Cooking Oil Tester (Temperature)TÜRKAK
08Curing TankTÜRKAK
09Deep FreezerMeasuring range:−80 °C ≤ T ≤ 250 °CTÜRKAK
10Dew Point MeterMeasuring range:20 %rh ≤ RH ≤ 90 %rhTÜRKAK
11Dry Block CalibratorITS-90Measuring range:−80 °C ≤ T ≤ 1200 °CTÜRKAK
12Drying FurnaceEURAMET cg-20 · DAkkS-DKD-R 5-7TÜRKAK
13Drying MachineTÜRKAKTraceable
14Drying OvenEURAMET cg-20 · DAkkS-DKD-R 5-7Measuring range:−80 °C ≤ T ≤ 250 °CTÜRKAK
15Ductility TesterTÜRKAK
16Fermentation RoomTÜRKAK
17Flash Point TesterTÜRKAK
18Glow Wire TesterTÜRKAK
19Humidity TransmitterMeasuring range:20 %rh ≤ RH ≤ 90 %rhTÜRKAK
20Hygrometer (Ambient)ITS-90Measuring range:20 %rh ≤ RH ≤ 90 %rhTÜRKAK
21IncubatorEURAMET cg-20 · DAkkS-DKD-R 5-7Measuring range:−80 °C ≤ T ≤ 250 °CTÜRKAK
22Liquid BathITS-90Measuring range:−80 °C ≤ T ≤ 250 °CTÜRKAK
23Liquid-in-Glass ThermometerITS-90Measuring range:−40 °C ≤ T ≤ 250 °CTÜRKAK
24Melting Point ApparatusTÜRKAK
25MFI / Melt Flow IndexerTÜRKAK
26Muffle FurnaceEURAMET cg-20 · DAkkS-DKD-R 5-7Measuring range:400 °C ≤ T ≤ 1200 °CTÜRKAK
27Multichannel Temperature CalibratorTÜRKAK
28Multifunction Temperature CalibratorMeasuring range:Thermocouple: −270 °C ≤ T ≤ 1370 °CMeasuring range:RTD: −200 °C ≤ T ≤ 650 °CTÜRKAK
29Oil BathITS-90Measuring range:−80 °C ≤ T ≤ 250 °CTÜRKAK
30OvenEURAMET cg-20 · DAkkS-DKD-R 5-7TÜRKAK
31Ozone Ageing ChamberTÜRKAK
32Pour Point TesterTÜRKAK
33PyrometerMeasuring range:−40 °C ≤ T ≤ 1200 °CTÜRKAK
34Radiation / Infrared ThermometerITS-90Measuring range:−40 °C ≤ T ≤ 1200 °CTÜRKAK
35Reference Resistance ThermometerITS-90Measuring range:−40 °C ≤ T ≤ 400 °CTÜRKAK
36Reference Thermo-hygrometerITS-90Measuring range:−30 °C ≤ T ≤ 150 °CMeasuring range:20 %rh ≤ RH ≤ 90 %rhTÜRKAK
37Reference Thermocouple ThermometerITS-90Measuring range:−40 °C ≤ T ≤ 1200 °CTÜRKAK
38Reference ThermometerMeasuring range:−40 °C ≤ T ≤ 1200 °CTÜRKAK
39Reference Thermometer (Indicator)Measuring range:−40 °C ≤ T ≤ 1200 °CTÜRKAK
40Refrigerated VehicleITS-90TÜRKAK
41RefrigeratorITS-90Measuring range:−80 °C ≤ T ≤ 250 °CTÜRKAK
42Resistance ThermometerITS-90Measuring range:−40 °C ≤ T ≤ 400 °CTÜRKAK
43RheometerITS-90TÜRKAK
44Room / Ambient ThermometerMeasuring range:−30 °C ≤ T ≤ 150 °CTÜRKAK
45Salt BathEURAMET cg-20 · DAkkS-DKD-R 5-7TÜRKAK
46Salt Spray Corrosion ChamberITS-90TÜRKAK
47Softening Point ApparatusTÜRKAK
48SteriliserEURAMET cg-20 · DAkkS-DKD-R 5-7Measuring range:−80 °C ≤ T ≤ 250 °CTÜRKAK
TÜRKAKwithin our TÜRKAK accreditation scope, certificate with accreditation markTraceablecalibration certificate traceable to national / international referencesrows with an arrow open all ranges and a scope check
Showing 48 / 91 devicesCan’t find your device on the list? Ask us →
From our laboratory

Temperature Devices

Some of the 91 device types in our calibration scope.

Temperature Device Calibration

This website only uses cookies that are necessary for the site to work. By continuing, you accept the use of these cookies. Cookie Policy